Coal preparation plants produce fines that escape the washing circuit: coal slurry with 3-10% solids that must be recovered or settled. Discharging this slurry wastes saleable coal, pollutes water and fills settling ponds that require expensive reclamation.
High-clay overburden in open-cut mines worsens the problem, creating slurry that barely settles even after days in the pond.
CauseCoal fines are hydrophobic and float, while clay minerals are hydrophilic and stay suspended. A flocculant must handle both: capture the coal particles for recovery and settle the clay fraction for clean overflow.
Anionic flocculants work on the clay but often fail to capture fine coal because the coal surface is non-polar and does not adsorb anionic polymers well.
SolutionThis cationic PolyDADMAC flocculant bridges both coal and clay particles. The cationic charge adsorbs onto clay surfaces, while hydrophobic interactions and charge patches capture coal fines into the same floc network.
In a coal washery treating 400 m³/h of slurry, 25-50 g/ton of this polymer cut overflow solids from 3,500 mg/L to 150 mg/L, recovered an extra 8 tons/day of fine coal, and reduced pond dredging frequency by half.
Key Features| Parameter | Specification |
|---|---|
| Appearance | Colorless to light yellow liquid |
| Solid Content | 40% ± 1% |
| Viscosity (25℃) | 8000-12000 cps |
| Charge Density | 5.5-6.5 meq/g |
| pH (1% solution) | 4.0-6.0 |
| Density (25℃) | 1.06-1.10 g/cm³ |
| Recommended Dosage | 20-60 g/ton of dry solids |
| Settling Time | 10-15 minutes |
For coal washing thickeners, fines recovery cyclones, slurry ponds and tailings dams in coal mining and processing. Also for coal-fired power plant ash pond water treatment.
Selection GuideIf overflow clarity is the priority, dose at the thickener feed well. If fine coal recovery matters more, dose earlier in the circuit, before the classifying cyclone. Test both points with a cylinder settle test.
FAQQ1: Can I recover the coal from the sludge? Yes. The flocculated sludge can be fed to a spiral or centrifuge to recover the coal fraction; the remaining clay tailings dewater more easily after polymer treatment.
Q2: Does it work in acidic mine drainage? Yes, stable at pH 3-9. At low pH, the cationic charge is stronger; reduce the dose by 20-30% in acidic circuits.
Q3: How does it compare to alum for coal slurry? Alum adds dissolved solids and produces more sludge. PolyDADMAC works at one-tenth the dose with no metal residual in the overflow.
Q4: Will it help with ash pond water? Yes, fly ash carries surface charge similar to clay. The same mechanism settles ash fines and clarifies the overflow for reuse in ash handling.
Trusted Global Supplier: Over 15 years of experience in manufacturing water treatment chemicals.
Complete Product Range: Full series of anionic, cationic, and nonionic PAMs tailored for different applications.
High Quality Standards: Strict quality control ensures stable performance and safety.
Global Reach: Exported to more than 100 countries with reliable supply capability.
Technical Support: Professional team provides laboratory testing, technical advice, and customized solutions.