logo
banner banner

Blog Details

Created with Pixso. Home Created with Pixso. News Created with Pixso.

Sudfloc 3870 Cationic Polyelectrolyte Coagulant Raises Drinking Water Clarity at 15-70 mg/L

Sudfloc 3870 Cationic Polyelectrolyte Coagulant Raises Drinking Water Clarity at 15-70 mg/L

2026-11-24

Sudfloc 3870 is a liquid cationic polyelectrolyte coagulant developed by Wuxi Oyi Environmental Technology for drinking water clarification, and it is now supplied to utilities across Nigeria, South Africa, Malawi and Botswana. The product carries an aluminium content of 17.5 to 23.5 percent expressed as Al2O3 together with a strong positive charge, so it destabilises the fine clay, silt and organic colloids that keep river and reservoir water persistently turbid. Operators dose between 15 and 70 mg/L at the raw water inlet, where a static mixer disperses the polymer within seconds and a dense floc begins to form. Because the reaction does not depend on a narrow pH window, plants treating soft rainwater, alkaline borehole water or slightly acidic reservoir water can run the same product without reformulating the treatment programme. This article explains the chemistry, the reasons plants switch to a cationic liquid programme, the dosing procedure used on site, and the questions buyers ask most often before placing a first order. The figures quoted here come from working plants rather than from laboratory trials alone.

What Is a Cationic Polyelectrolyte Coagulant

A cationic polyelectrolyte coagulant is a water soluble polymer carrying positively charged groups along its chain. When it enters raw water, those positive sites neutralise the negative surface charge that keeps colloidal particles apart, and the long polymer chain then bridges neighbouring particles into aggregates large enough to settle or be filtered out. Sudfloc 3870 delivers this mechanism in a ready to use liquid form, so plants avoid the dissolving tanks, dust control and labour that powder coagulants require.

The physical specification is the practical starting point for any plant engineer. Sudfloc 3870 is a colourless to light yellow liquid with a specific gravity between 1.20 and 1.30 grams per millilitre and a Brookfield viscosity between 10 and 100 centipoise, which keeps it pumpable with ordinary diaphragm or peristaltic dosing equipment. Insoluble matter is held at or below 0.001 percent, and the pH of a 15 percent aqueous solution sits between 3.0 and 5.0. Trace contaminants are controlled tightly, including total iron at or below 0.001 percent, arsenic at or below 0.0002 percent, hexavalent chromium at or below 0.0001 percent, and lead, cadmium and mercury at or below 0.001, 0.0001 and 0.00001 percent respectively.

The key parameters are summarised below.

Because the active content is high, one tonne of product treats a large volume of water, which reduces freight cost per cubic metre and keeps chemical storage compact on sites with limited floor space. The liquid is fully miscible with water at any ratio, and dilution to a working strength of 2 to 50 percent is standard practice before metering.

ParameterSpecification
AppearanceColourless to light yellow liquid
Total aluminium as Al2O317.5 - 23.5 percent w/w
Specific gravity1.20 - 1.30 g/ml
Viscosity, Brookfield10 - 100 cps
Insoluble matter0.001 percent max
pH, 15 percent solution3.0 - 5.0
Total iron0.001 percent max
Arsenic0.0002 percent max
Recommended dosage15 - 70 mg/L

Why Cationic Polyelectrolyte Coagulant Matters to Water Plants

The operational case for a cationic liquid coagulant is built on the problems that conventional programmes leave unsolved. Surface water quality in West and Southern Africa changes faster than most treatment plants can respond, and each change exposes a weakness in the coagulant regime.

Secondary benefits matter to buyers searching for surface water treatment chemicals, potable water coagulant suppliers or cationic polymer for clarifier upgrading. The product is compatible with organic flocculants, so a plant can keep its existing anionic or nonionic programme downstream and use Sudfloc 3870 purely as the coagulation step. It is also suited to pre-treatment ahead of ultrafiltration and reverse osmosis, where organic and colloidal fouling shortens membrane life.

  • Turbidity spikes after rainfall. A river that runs at 20 NTU at the end of the dry season can exceed 2000 NTU within hours of the first storm. Alum based programmes respond slowly because the reaction depends on alkalinity and pH, and clarifier blankets collapse while operators adjust. A cationic polymer with high charge density destabilises particles immediately, so settled water clarity recovers within the same shift.
  • Filter protection. Every kilogram of solids that passes the clarifier is a kilogram that the sand filters must capture. When floc is weak, filters blind early, backwash demand rises, and filtered water turbidity drifts upward. Because Sudfloc 3870 produces a dense, compact floc, filter run lengths extend and the plant keeps its treated water inside the limits set by national drinking water standards.
  • Wide pH tolerance. Many plants treat several sources through one works, mixing reservoir water with borehole water as availability changes. A coagulant that works from mildly acidic to mildly alkaline conditions removes the need to re-optimise lime dosing every time the source blend changes, which is a significant saving in operator time and in chemical consumption.
  • Low sludge volume and simple handling. Better solids capture means less waste sludge to dewater, haul and dispose of, and that cost is often larger than the coagulant bill itself. On the handling side, a liquid product removes dust exposure, dissolving tanks and manual weighing, which matters on sites with limited laboratory support and trained staff.
  • Predictable behaviour during plant upsets. When a works loses power, a transfer pump trips or a clarifier is taken out for repair, the coagulant programme is usually the first element blamed for the resulting turbidity excursion. A liquid cationic product with a stable specification removes one variable from that investigation, because the dose responds to raw water rather than to the age of the chemical or the way it was dissolved that morning.

    One further practical point is worth stating for procurement teams. Because the product is a single liquid with a twelve month shelf life, a plant can hold buffer stock without the quality drift that affects powder coagulants stored in humid conditions. On sites where deliveries are infrequent and storage is a corridor behind the pump room, that reliability is worth as much as the chemical itself.

How to Apply It on Site

Deploying the product on a working plant follows five practical steps, each of which is normally confirmed during a single site visit.

Step 1: Confirm the dosing point and mixing energy

The coagulant must be injected where turbulence is highest, typically at the raw water inlet immediately upstream of a static mixer or flash mixer, with at least 30 seconds of rapid mix available. Plants that inject into a calm channel see polymer consumed by local over-dosing and incomplete dispersion, and they report poor results that are blamed on the product rather than the injection point.

Step 2: Run a jar test series across the dosage band

Prepare six beakers of raw water and dose 15, 25, 35, 50, 60 and 70 mg/L of product, then apply 1 minute of rapid mix at 200 rpm and 15 minutes of slow mix at 40 rpm. Record settled turbidity after 20 minutes and filtered turbidity after a 0.45 micron pass. The lowest dose that brings settled turbidity within 2 NTU of the best result is the operating point, and it is normally between 20 and 40 mg/L for river water and toward the lower end for reservoir water.

Step 3: Set the dilution and metering arrangement

Dilute to 2 to 50 percent working strength in a day tank with gentle agitation, and use a diaphragm metering pump sized for the required flow at the lowest credible raw water turbidity. Diluted solution should be consumed within a few days; standing dilute polymer supports biological growth that fouls lines and injectors.

Step 4: Establish the control regime

Record raw water turbidity, dosed volume, settled turbidity and filtered turbidity every four hours during the first week, then shift to a daily record once the pattern is stable. When raw turbidity doubles, expect the required dose to rise by roughly 40 to 60 percent with this product; the floc remains stable at that higher dose without the pH drop that alum would cause.

Step 5: Verify compatibility downstream

Check filter run length, backwash water consumption and sludge volume before and after the switch. Plants in Nigeria and Malawi that moved from alum to Sudfloc 3870 typically report 20 to 35 percent longer filter runs and a visible reduction in sludge haulage, which is the evidence most finance teams ask for when approving a change of coagulant.

Step 6: Manage the transition weeks after switching

Keep the previous coagulant available for two weeks after the changeover and run settled and filtered turbidity checks every four hours during that period. Most issues appear in the first three days and are caused by residual chemical in the day tank or by a dosing line that still holds the old product. Flush the tank, recalibrate the pump and confirm the injection quill is clear before concluding that the new product behaves differently.

Step 7: Document the programme for the next operator

Write a one page operating sheet covering the dose ladder, the jar test method, the sampling points and the escalation trigger for filtered turbidity. Plants that keep this sheet at the dosing point recover far faster after staff changes, and it is the document an auditor will ask for when turbidity records are reviewed.

Frequently Asked Questions

What dosage of Sudfloc 3870 should a plant start with?

Start at 20 mg/L for river water and 15 mg/L for low turbidity reservoir water, then optimise by jar test. The working band is 15 to 70 mg/L, and the upper end is only needed during flood turbidity or heavy algal load. Confirm the figure with a jar test on the day of delivery.

Is Sudfloc 3870 suitable for potable water production?

Yes. It is formulated for drinking water clarification with tightly controlled trace metals, including arsenic below 0.0002 percent and mercury below 0.00001 percent. Local approval still depends on national registration requirements in the buyer's country. Registration is managed by the importing utility or its agent. Registration requirements are set by the importing country authority.

Can it replace alum completely?

In most surface water plants it can replace alum as the primary coagulant. Where alkalinity is very low, some operators keep a small alum or lime dose for pH and alkalinity correction, but the clarification duty is fully covered by the polymer. Some plants retain a small lime dose for alkalinity control.

How is the product stored?

Store in the original closed container in a cool, dry place away from heat, flame and direct sunlight. Shelf life is twelve months unopened, and the liquid should not be allowed to freeze because viscosity rises sharply after freezing. Avoid freezing, which raises viscosity sharply. Never allow the product to freeze in transit or in store.

What packaging is available?

Standard packing is a 250KG high density polyethylene drum, four drums per pallet, twenty drums per 20GP container. A 1250KG IBC with bottom discharge valve is available for plants consuming more than a tonne per week. Twenty drums fit a 20 foot container. Each drum carries a batch certificate with full trace metal data.

Does it work at low water temperature?

Performance remains good at low temperature because the charge neutralisation step is not strongly temperature dependent. Floc growth is slightly slower below 10 degrees Celsius, so a modest dose increase of 10 to 20 percent is often applied in winter. Increase dose by 10 to 20 percent below 10 degrees Celsius. Below 10 degrees Celsius a modest dose increase is normal practice.

Conclusion

Sudfloc 3870 gives drinking water plants a liquid cationic polyelectrolyte coagulant that responds quickly to changing raw water, protects filters and reduces sludge without demanding new civil works. Its 17.5 to 23.5 percent Al2O3 content and wide pH tolerance mean one product serves river, reservoir and borehole sources at a dosage band of 15 to 70 mg/L. Buyers evaluating a coagulant switch should request a sample, run the five step trial described above, and compare filter run length and sludge volume against the incumbent programme. Wuxi Oyi Environmental Technology supplies the grade in 250KG drums and 1250KG IBC with batch certificates covering aluminium content, density, viscosity, pH and regulated trace metals. A single jar test series and a written ladder are usually enough to make the switch permanent.