logo
banner banner

Blog Details

Created with Pixso. Home Created with Pixso. News Created with Pixso.

Sudfloc 3835 Alumina salt Blend Cuts Coagulant Cost in Municipal Water Plants

Sudfloc 3835 Alumina salt Blend Cuts Coagulant Cost in Municipal Water Plants

2025-10-21

Sudfloc 3835 is an alumina salt blended with cationic polymer in a single liquid product, supplied by Wuxi Oyi Environmental Technology for municipal water plants treating variable surface water. Each active fraction contributes 15 to 25 percent by weight, so one drum delivers both charge neutralisation and polymeric bridging at the clarifier inlet. Plants that previously ran alum plus a separate polymer now dose a single product at 15 to 70 mg/L, cutting chemical handling, storage and operator time while improving settled water clarity. The blend is particularly effective where raw water swings between low turbidity, high colour conditions and short, intense turbidity peaks after rain, because the pre-hydrolysed aluminium fraction handles mineral load while the cationic polymer controls colour and algae derived organics. This article sets out the chemistry, the commercial case for replacing two chemicals with one, the dosing procedure used at municipal works, and the practical questions procurement teams raise before switching suppliers.

What Is a Alumina salt Coagulant

It is a pre-hydrolysed aluminium salt with the general behaviour of a highly charged inorganic coagulant. Compared with aluminium sulphate, it carries a much higher basicity, so it consumes far less alkalinity and produces less residual sludge for the same clarification duty. Cationic organic polymer built from diallyl dimethyl ammonium chloride units, and it works by charge neutralisation and bridging rather than by sweep flocculation.

Sudfloc 3835 combines the two in one stable liquid. The specification calls for cationic polymer at 50 percent and alumina salt at 50 percent, with the balance being water. Appearance is a light yellow clear liquid with a specific weight of 1.18 to 1.25 grams per millilitre at 25 degrees Celsius, a viscosity of 20 to 100 centipoise at 20 degrees Celsius, water insoluble matter at or below 0.1 percent, and a pH of 2.0 to 5.0 in one percent solution.

Because both fractions are already in solution, the product needs no on site mixing of two chemicals, and the ratio between the inorganic and organic components stays constant from batch to batch. That consistency is what allows a plant to hold a stable dosage point across seasons rather than re-optimising every time a delivery arrives.

The stability of the blend deserves a note as well. Because both fractions are already dissolved and the ratio between them is fixed at manufacture, the product does not separate in storage and needs no agitation beyond gentle recirculation. Plants that previously mixed alum liquor and polymer on site often report fewer dosing errors simply because there is nothing left to mix. The specification also fixes water insoluble matter at or below 0.1 percent, which keeps injection nozzles and filter media clean over long campaigns.

Parameter Specification
Appearance Light yellow clear liquid
Specific weight at 25 C 1.18 - 1.25 g/ml
Viscosity at 20 C 20 - 100 cps
Water insoluble matter 0.1 percent max
pH, 1 percent solution 2.0 - 5.0
Recommended dosage 15 - 70 mg/L
Why Alumina Salt Coagulant Matters to Water Plants

Municipal water plants rarely have the luxury of a single, stable raw water source. They treat whatever the catchment delivers, and the cost of that variability shows up in chemical consumption, filter maintenance and staff time.

For buyers comparing coagulant suppliers, the relevant long tail searches are usually dual component coagulant, potable water coagulant liquid, and low alkalinity consumption coagulant. Sudfloc 3835 answers all four with one specification, and it remains compatible with downstream anionic or nonionic flocculants where a plant wants to keep a polishing polymer in the train.

  • One chemical instead of two. A conventional programme doses alum at the inlet and a polymer before the filters, which means two storage areas, two dosing skids, two sets of calibration routines and twice the stock administration. Substituting Sudfloc 3835 removes one entire feed system, and the savings in pumps, spares and operator attention are usually larger than the difference in chemical price.
  • Lower alkalinity demand. Pre-hydrolysed aluminium chloride consumes substantially less bicarbonate alkalinity than aluminium sulphate, so plants on soft or low alkalinity sources stop fighting pH depression and can reduce or eliminate lime dosing. On a plant treating 20 million litres per day, that change alone often pays for the coagulant upgrade.
  • Faster, denser floc. The cationic polymer fraction bridges particles that the aluminium fraction has already destabilised, producing a floc that settles quickly and compacts well. Utilities in Nigeria, Malawi, Botswana and South Africa use this behaviour to lift plant output without new sedimentation capacity, simply by operating existing clarifiers at a higher rise rate.
  • Reduced sludge and disposal cost. Better solids capture means less sludge volume, easier dewatering and fewer tanker movements to the disposal site. Where sludge disposal is contracted at a fixed price per tonne, the reduction converts directly into budget relief.
  • Fewer operator decisions per shift. Every additional chemical on a plant is another calibration, another stock count and another opportunity for error on a night shift with a single operator. Collapsing two feeds into one removes a decision point, and the effect on dosing consistency is usually visible in the turbidity record within a month.

    For utilities comparing coagulant options, the honest test is total cost per megalitre treated, not price per tonne. Once pump spares, storage, calibration time and sludge disposal are counted, a blended product frequently wins even when its invoice price is higher than alum. Plants in Botswana and South Africa that ran this calculation during a tariff review found the blended programme cheaper in six of seven works studied.

How to Apply It on Site

Switching a municipal works to the blended product is a controlled exercise that can be completed in about three weeks without interrupting supply.


Step 1: Characterise the raw water range

Collect samples across at least four weeks, covering dry season and any rainfall event, and record turbidity, colour, alkalinity, pH and temperature. The blend is most valuable where these parameters move widely, because a single product then covers conditions that previously required two different coagulant regimes.

Step 2: Compare against the incumbent with jar tests

Run parallel series on the incumbent programme and on Sudfloc 3835 at 15, 25, 40, 55 and 70 mg/L. Judge on settled turbidity, filtered turbidity, floc size after five minutes, and the volume of settled sludge after 30 minutes. Plants typically find the blend matches or beats settled turbidity at 15 to 25 percent lower total chemical cost once the separate polymer dose is removed.

Step 3: Convert the dosing skid

Because the product is a single liquid, the polymer line is normally isolated and the aluminium line is re-rated for the new flow. Dilute to 2 to 50 percent working strength, calibrate the metering pump against a measured drawdown over ten minutes, and confirm the injection point gives at least 30 seconds of rapid mix.

Step 4: Fix the operating window

Start at 30 mg/L and adjust in steps of 5 mg/L against settled turbidity. Keep the pre-hydrolysed aluminium fraction in mind when setting lime dose: most plants find they can cut lime by 30 to 100 percent, and alkalinity should be monitored daily for the first month to confirm the new equilibrium.

Step 5: Audit filters and sludge after 30 days

Compare filter run length, backwash volume and sludge tonnes against the previous month. Utilities in Burkina Faso and Mali that completed this audit reported longer runs and fewer clarifier upsets during the first rainy season on the new programme, which is the practical proof that the blend is doing both jobs at once.

Step 6: Rebuild the lime and alkalinity strategy

Because pre-hydrolysed aluminium consumes less alkalinity, the existing lime dose will almost certainly be too high after the switch. Reduce it in steps of 20 percent while monitoring pH and alkalinity daily, and stop when filtered water pH sits comfortably inside the regulatory band. Keep the reduction recorded, since it is one of the clearest savings to report to management.

Step 7: Retrain the shift team on the new failure signatures

With a blended product, the classic symptom of over-dosing is a rising settled turbidity accompanied by a rising dose, which is the opposite of what operators trained on alum expect. A short session covering charge reversal, floc appearance and the correct response saves weeks of confused adjustment.

Step 8: Review the contract and stock policy

Set the buffer stock at four to six weeks of average consumption and confirm that the packaging format matches the site's lifting equipment. Plants that consume more than a tonne per day should move to 1250KG IBC at the same time as the chemistry change, because the handling saving is realised immediately.

Frequently Asked Questions
What is the difference between Sudfloc 3835 and ordinary alum?

Alum is aluminium sulphate, which needs alkalinity to react and produces large sludge volumes. Sudfloc 3835 blends pre-hydrolysed alumina salt and cationic polymer, so it works across a wider pH range with less alkalinity consumption and a denser floc. Dose at the raw water inlet with at least 30 seconds of rapid mix.

What dosage is recommended?

Dose between 15 and 70 mg/L at the raw water inlet. Most municipal plants settle between 25 and 45 mg/L, confirmed by jar test against their own water across the full seasonal turbidity range. Most plants settle between 25 and 45 mg/L after jar testing. High rise rate clarifiers may still use a small polishing flocculant.

Can the product be stored outside?

It can be stored outdoors in shade, because containers are UV stabilised, but the product must not freeze and should stay below 40 degrees Celsius. Shelf life is twelve months in the unopened original container. Shaded outdoor storage is acceptable if freezing is avoided. Dispatch is normally 7 to 12 working days after deposit is received.

Does the blend replace the need for a flocculant?

In many plants it does, because the cationic polymer fraction provides bridging. Where very high clarifier rise rates or sludge thickening duty exist, a small anionic or nonionic flocculant downstream may still add value. High rise rate clarifiers may still benefit from a polishing flocculant. Floc appears within seconds and reaches settleable size in minutes.

Which markets does the supplier serve?

Wuxi Oyi Environmental Technology supplies Nigeria, South Africa, Burkina Faso, Mali, Mauritania, Malawi, Botswana and other export markets, shipping in 250KG drums or 1250KG IBC with batch certificates of analysis. Typical dispatch is 7 to 12 working days after deposit. Tender support includes data sheets, certificates and sample quantities. Ask for a reference list from comparable utilities in the region before awarding the first contract.

How quickly does floc form after dosing?

Visible floc normally appears within 10 to 20 seconds of dispersion and reaches settleable size within two to three minutes, which is faster than most single component aluminium programmes at the same turbidity. Dispersion takes seconds and settleable floc forms within three minutes. Each container carries a batch certificate with trace metal results.

Conclusion

Sudfloc 3835 replaces two chemicals with one liquid blend of alumina salt and cationic polymer, each at 15 to 25 percent active content. Municipal plants gain faster floc, lower alkalinity demand, less sludge and a simpler dosing arrangement at a working dose of 15 to 70 mg/L. The practical test is a parallel jar test series on the plant's own water, followed by a 30 day audit of filter run length and sludge volume. Buyers who want a single specification that covers both mineral turbidity and colour loading can request samples and a batch certificate from Wuxi Oyi Environmental Technology before committing to a first container. Utilities that also convert to 1250KG IBC at the same time realise the handling saving immediately rather than at the next contract renewal. Requesting a sample from a current production batch shortens the evaluation to a single week.