Coagulant dosage optimization is the single operating skill that decides whether a surface water plant meets its turbidity limit at a sensible chemical cost. Wuxi Oyi Environmental Technology publishes this working guide based on plants using its Sudfloc and Algaefloc cationic liquid coagulants, where the practical dosing band runs from 15 to 70 mg/L depending on raw water conditions. Over-dosing wastes chemical, raises sludge volume and can carry floc over clarifier weirs; under-dosing leaves filters to capture solids they were never designed to hold. The difference between the two is usually a jar test series and a written dose ladder, both of which can be established in a single day. This article sets out the procedure, the interpretation rules, the seasonal adjustments and the common errors that make a correct dose look wrong on a plant. The guide is built from operating data rather than laboratory averages alone. Every figure below is a starting point, not a set point.
Coagulant dosage optimization is the process of finding the lowest coagulant dose that reliably produces settled and filtered water within specification across the range of raw water conditions the plant actually experiences. It is not a single number and it is not a supplier recommendation taken from a data sheet. It is a relationship between raw water quality, mixing energy, coagulant chemistry and target turbidity.
The mechanisms behind that relationship are charge neutralisation and bridging. Particles in raw water carry a negative surface charge that keeps them apart. A cationic coagulant supplies positive charge to neutralise that barrier, and the polymer chain then links neighbouring particles into aggregates. Below the optimum dose, charge remains and particles repel each other, so the water stays turbid. Above it, the particle surfaces reverse charge and the floc re-stabilises, which is why over-dosing can look exactly like under-dosing on a turbidity meter.
For the Sudfloc and Algaefloc liquid range, the working band is 15 to 70 mg/L. Within that band, typical operating points are 15 to 25 mg/L for low turbidity reservoir water, 25 to 40 mg/L for river water in normal conditions, 40 to 55 mg/L for seasonal turbidity peaks and 55 to 70 mg/L for flood events or heavy blooms.
Every value in that table is a starting point, not a set point. The set point comes from the plant's own water, and the instrument that produces it is a jar tester.
The band is deliberately wide because raw water quality across the region varies more than most published dosing tables assume.
| Raw water condition | Typical dose band | Control check |
|---|---|---|
| Reservoir, low turbidity, high colour | 15 - 25 mg/L | Settled turbidity below 3 NTU |
| River, normal conditions | 25 - 40 mg/L | Settled turbidity below 5 NTU |
| Seasonal peak turbidity | 40 - 55 mg/L | Filter run length stable |
| Flood or heavy algal bloom | 55 - 70 mg/L | Filtered turbidity below 1 NTU |
Plants that skip dosage optimization pay for it three times: in chemical, in sludge disposal and in filter maintenance.
Buyers searching coagulant dose calculation, jar test procedure for water treatment, optimum coagulant dose or coagulant dose per cubic metre will find dozens of formulas. The reliable method is empirical, and it costs one working day per plant to complete.
A plant that measures its own optimum also negotiates better, because it knows what the chemical is actually doing rather than what the data sheet claims.
There is a training value too. Staff who understand why over-dosing re-stabilises particles make better decisions during an upset than staff who have memorised a single figure. The jar test is the cheapest teaching tool available: six beakers, twenty minutes and one turbidity meter will change how an operator thinks about the process permanently. Buyers evaluating a coagulant supplier should ask whether jar test support and a dose calculation sheet are included, because those materials are worth more than a small price difference.
The procedure below is the version used during commissioning visits and it can be repeated by plant staff whenever raw water quality changes materially.
Use a six position jar tester with variable speed, a turbidity meter calibrated the same day, and a 0.45 micron filter for the filtered turbidity check. Collect 20 litres of raw water in a clean container and begin the test within two hours, keeping the sample out of sunlight. Record turbidity, pH, colour, alkalinity and temperature before dosing.
Dose 15, 25, 35, 50, 60 and 70 mg/L across the six beakers, adding product as a one percent working solution so the volumes are measurable. Include one beaker with no coagulant as a control, and if the plant is switching from another chemical, run a parallel series with the incumbent for comparison.
Rapid mix at 200 rpm for 60 seconds, then slow mix at 40 rpm for 15 minutes, then settle for 20 minutes without stirring. Sample settled water from 5 centimetres below the surface, measure turbidity, then filter a portion and measure filtered turbidity.
Plot settled turbidity against dose. The curve falls to a minimum and then either flattens or rises. Select the lowest dose within 2 NTU of the minimum, not the absolute minimum, because the flattening region gives tolerance for normal raw water variation. If the curve is flat across the whole series, the limiting factor is mixing energy or pH rather than dose, and that should be corrected first.
Convert the chosen dose to pump stroke using a measured drawdown calibration, post the dose ladder near the dosing point, and record daily settled and filtered turbidity. Repeat the jar test series at every significant raw water change: after the first rains, at the start of a bloom season, and whenever settled turbidity drifts for two consecutive shifts without an obvious cause.
Jar test mixing is more ideal than plant mixing, so the plant optimum is often 10 to 20 percent higher than the beaker optimum. Compare the two, adjust once, and record the offset for the site. Ignoring this difference is the most common reason a correct jar test produces an incorrect plant setting.
Backwash water recycled to the plant head carries solids and polymer residue, which raises coagulant demand. Measure the recycle flow and its turbidity, and test a sample blended with raw water at the real recycle ratio to see the true demand rather than the demand of raw water alone.
At the end of the rains, compare recorded doses against the ladder and update it with the observed values. A ladder that is revised once a year converges quickly on the plant's real behaviour, and it becomes the single most useful operating document the works owns.
For cationic liquid coagulants the practical band is 15 to 70 mg/L. Reservoir water usually sits at 15 to 25 mg/L, normal river water at 25 to 40 mg/L, and flood or bloom conditions at 55 to 70 mg/L. Repeat after the first rains and at the start of each bloom season.
Above the optimum dose, excess positive charge reverses the particle surface charge, so particles repel again and the floc becomes fine and unstable. This charge reversal looks like under-dosing on a turbidity meter. Colour, alkalinity and organic load all affect demand. Colour, alkalinity and organic load all raise coagulant demand.
Repeat after the first rains, at the start of a bloom season, after any change of raw water source or chemical supplier, and whenever settled turbidity drifts for two consecutive shifts without explanation. Matching the plant's mixing energy makes results transferable. Matching plant mixing energy makes the result transferable. A seasonal review of the ladder is also worth scheduling alongside the jar test series.
Turbidity is a useful first estimate, but colour, alkalinity, pH and organic load all affect demand. A dose ladder indexed to turbidity bands, calibrated by jar test, is more reliable than a formula. Calibrate by drawing the pump into a graduated container. Calibrate by drawing the pump into a graduated container.
Use 200 rpm for 60 seconds of rapid mix, 40 rpm for 15 minutes of slow mix and 20 minutes of quiescent settling. Matching the plant's actual mixing energy makes the result transferable. Select the lowest dose within 2 NTU of the minimum. Note any systematic offset between beaker and plant results.
Draw the pump for a measured time into a graduated container, calculate litres per hour, then convert the required mg/L dose and plant flow into litres per hour of working solution strength. Note any systematic offset between beaker and plant results. Recycle streams raise demand and should be tested with the raw water.
Coagulant dosage optimization is a one day exercise that pays back every month thereafter. The 15 to 70 mg/L band is the starting map, the jar test series is the instrument, and the dose ladder is the operating system that keeps a plant stable across seasons. Plants that repeat the series at each significant raw water change typically reduce chemical consumption by 10 to 20 percent and cut backwash water use at the same time. Wuxi Oyi Environmental Technology supports customers with jar test templates, dose calculation sheets and batch certificates across the Sudfloc and Algaefloc ranges. One day of testing per season is enough to keep the ladder calibrated, and it is the cheapest saving available to most plants. Rerunning the series after the first rainy season is the habit that keeps the saving.